<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-03 14-17-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 51 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 71 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19048 0,7402
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,7 dBr 3,47 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 14:17, 3.05.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,7402 Acquired: 2026/05/03 14.16.42 Total samples: 19048 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,3 dBr MIN: 0,7 dBr AVE: 3,47 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2026/05/03 14.16.42) 14.02 14.04 14.06 14.08 14.10 14.12 14.14 14.16 0 2 4 6 Pm [dBr]